Return
Print
Email
RELAY SAF 2.5A 6NO 24VDC
IDW_IMAGE_1521035374532.jpeg

RELAY SAF 2.5A 6NO 24VDC by Schneider Electric Square D

  • Part Number: XPSAV11113
  • UPC: 00786000000000
  • Availability:
Quantity:
Add To Quote
Add To Estimate
Add To Wishlist
Compare Item
Product Overview
Schneider Electric Preventa™ XPSAV11113 Electronic Internal Safety Relay, 2.5 A, 6NO Contact Form, 24 VDC Coil
Specifications
Details
Amperage Rating:
2.5
APPLICATION:
Safety Automation, Emergency Stop and Switch Monitoring Applications
Approvals:
ARRA Compliant|Buy American Act Compliant|RoHS Compliant|CSA Certified|UL Listed|TUV Standard|EN 1088/60204-1/13850/60947-5-1|ISO 14119/13850|IEC 60947-5-1|PROP65: This product can expose you to chemicals including: Lead and lead compounds which is known t
BRAND NAME:
Schneider Electric
Category:
Safety Relays
Coil Voltage:
24
Contact Form:
6NO
COUNTRY OF ORIGIN:
ID
Dimensions:
3.89 in L x 4.49 in W x 1.77 in H
Display:
LED
Enclosure Type:
IP20/IP40
Frequency Rating:
50/60
HEIGHT:
2.5 IN
LENGTH:
6.4 IN
Mounting Type:
DIN Rail
PART NUMBER:
ESD_901444
Power Rating:
5
PROP 65:
View
Series:
XPSAV
Subcategory:
Industrial Control
Subtype:
Relays
Temperature Rating:
-10 to 55
Terminal Type:
Captive Screw Clamp
Type:
Electronic Internal
UNSPSC:
32151802
VOLUME:
72 CI
WARRANTY:
18 Months
WEIGHT:
0.94 L
WIDTH:
4.5 IN
Manufactured By:
Schneider Electric Square D
Other Details
<= 30 ms response time on input open
10 mA for relay output minimum output current
100 Ohm line resistance
17 VAC for relay output minimum output voltage
20 A for relay output conventional free air thermal current
300 VAC rated insulation voltage
4 kVAC rated impulse withstand voltage
C300 breaking capacity
Emergency stop button with 1 NC contact, automatic start or unmonitored start
Emergency stop button with 2 NC contacts, monitored start
Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
In addition to the stop category 0 instantaneous opening safety outputs (3 for XPSAV), the modules incorporate stop category 1 time delay outputs (3 for XPSAV) which allow for controlled deceleration of the motor components until a comp
Module XPSAV also incorporates 3 solid state signaling outputs for signaling to the process PLC
Monitoring of a movable guard associated with 2 switches automatic start
They provide protective for both the machine operator and the machine by immediately stopping the dangerous movement on receipt of a stop instruction from the operator, or on detection of a fault in the safety circuit itself
To aid diagnostics, the modules have LEDs which provide information on the monitoring circuit status